Why open-access buyers pay it
Industrial and commercial tariffs in India are set above the cost of supply, so that tariffs for farms and homes can be kept lower. When a factory buys its power elsewhere through open access, the DISCOM (distribution company) loses that contribution. The cross-subsidy surcharge recovers it on each unit the factory takes through open access.
How the surcharge is calculated
The Tariff Policy, 2016 gives the formula: S = T − [C / (1 − L/100) + D + R], where S is the surcharge, T the tariff payable by your consumer category, C the DISCOM's per-unit cost of power purchase, L the aggregate system losses (in %) at your voltage level, D the per-unit wheeling charge at that voltage, and R the per-unit cost of carrying regulatory assets. The same policy caps the surcharge at 20% of the tariff applicable to the consumer category. Each state commission works out its own figure in its tariff orders.
Who does not pay it
- Captive and group captive users whose plant meets the 26% ownership and 51% consumption tests: the Electricity Act exempts them.
- Rooftop and other behind-the-meter plants: the power never travels over the DISCOM's network, so it is not open access.
For green open access, the 2022 rules also cap any increase in the surcharge at 50% over the 12 years from the start of open access. Rules as of Nov 2026.
Illustrative example
Worked example: what the surcharge can cost
A third-party open-access buyer taking 50 lakh units a year.
- Grid tariff for the category
- ₹8.00 per kWh
- Maximum surcharge at 20% of tariff
- ₹1.60 per kWh
- Annual surcharge at that ceiling
- 50 lakh × ₹1.60 = ₹80 lakh
Under a qualifying group captive structure, the same power carries no cross-subsidy surcharge.
Illustrative numbers. Your state's actual surcharge is published in its latest tariff order.
What to check in an open-access proposal
- The surcharge used in the proposal, and which tariff order it comes from
- Whether the proposal assumes captive status, and who carries the risk if the plant fails verification
- How the surcharge is escalated over the contract term
- Whether the green open access cap on increases applies to you
Where group captive removes the surcharge
We build offsite solar wheeled to your plant, for loads larger than your roof can serve. Where the group captive tests can be met, that power carries no cross-subsidy surcharge.
Sources
- KSERC: cross-subsidy surcharge formula under the revised Tariff Policy of 28 January 2016 (opens in a new tab)
- Tariff Policy 2016 proviso capping the surcharge at 20% of tariff, as quoted in an APERC order (opens in a new tab)
- JMK Research: Green Energy Open Access Rules 2022, summary of provisions (opens in a new tab)
- Power Line: Electricity (Amendment) Rules, 2026 and captive users (opens in a new tab)