Plant performance

CUF: capacity utilisation factor

Capacity utilisation factor (CUF) is the energy a plant produced in a period divided by what it would have produced running at full rated capacity every hour of that period.

What CUF tells you

CUF answers a simple question: for each kilowatt of capacity, how much energy did the plant deliver over the year? Because a solar plant produces nothing at night and little on cloudy days, its CUF is far below 100%. It is a useful way to compare plants at different locations or to sense-check a generation estimate.

AC or DC: say which

CUF can be calculated on the plant's DC capacity (kWp of modules) or its AC capacity (kW of inverters). When the DC/AC ratio is above 1, which is normal, CUF on an AC basis is higher than on a DC basis for the same plant. Two proposals quoting CUF on different bases can look different while promising the same output.

CUF, PR and specific yield

  • CUF measures output against round-the-clock capacity. It moves with the weather and the location.
  • Specific yield is the same information in kWh per kWp per year.
  • Performance ratio measures output against the sunlight that arrived, so it shows how well the plant is being run.

Utility-scale tenders in India commonly fix a declared CUF the developer must meet. For a factory rooftop plant, a generation or PR guarantee is usually the more useful contract measure.

Illustrative example

Worked example: one plant, two CUFs

A plant with 1,000 kWp of modules and 800 kW of inverters generates 13,00,000 kWh in a year.

CUF on DC capacity
13,00,000 ÷ (1,000 × 8,760) = 14.8%
CUF on AC capacity
13,00,000 ÷ (800 × 8,760) = 18.6%
Specific yield
13,00,000 ÷ 1,000 = 1,300 kWh/kWp

Same plant, same year: the basis changes the number.

Illustrative numbers.

When a proposal quotes CUF

  • Is it on AC or DC capacity?
  • Is generation measured at the inverter or at the export meter?
  • Which weather data was used, and for which year?
  • Is it a guaranteed figure or an estimate?

Monitoring the plants we maintain

Every plant we maintain is monitored on Asset Connect, which tracks generation, PR and irradiance and feeds monthly engineer-signed reports.

See our monitoring software

Related terms

  • Plant performance

    Performance ratio (PR)

    Of the energy a plant could have produced from the sunlight that reached it, the share it delivered. The standard measure of how well a plant is run.

  • Plant performance

    Specific yield

    Energy generated per unit of installed capacity, in kWh per kWp per year. It depends mainly on location, tilt and shading, and lets you compare plants of different sizes.

  • Plant performance

    DC/AC ratio

    A plant's DC module capacity (kWp) divided by its AC inverter capacity (kW). A ratio above 1 keeps inverters busier through the day, at the cost of some midday clipping.

  • Plant performance

    kWp vs kW

    kWp is a plant's DC module capacity under standard test conditions; kW usually means AC power, such as the inverters' rated output or the power your factory draws.

Keep reading

Free feasibility study

Ask how we track generation on your plant

The feasibility study is free, takes 7 days and carries no commitment. An engineer replies within 48 hours.

What the study covers

  • Financial ROI sheet based on a preliminary design
  • Policy check for your state and connection
  • Roof feasibility and the area available for installation
Call us+91 22 4618 3484Get a free feasibility study